Do not open wet, damaged or energised outdoor electrical equipment
Water, damaged seals and outdoor cable faults can create serious shock risk. Leave affected circuits isolated and use a registered electrician for fixed outdoor wiring, submains and wet accessories.
MOST LIKELY CAUSES
Start with these
Symptom variations Match the exact behaviour before testing. ⌄
- All garden lights are dead
- One group is dead
- Lights fail after rain
- Lights work only in test mode
- RCD trips when lights switch on
Quick checks Safe external checks only. ⌄
- Check the house consumer unit and any local outdoor board or RCD.
- Disconnect portable outdoor appliances and extension leads.
- Check indoor fused spurs, switches and isolators supplying the area.
- Look for rain damage, condensation, cracked covers and loose cable entries.
- Attempt one controlled reset only if all equipment is dry and undamaged.
Fix 1 — Check controls after dark Follow this check without opening live or wet electrical equipment. ⌄
Process
Review timers, photocells, smart controls and manual overrides.
Fix 2 — Check local transformer or driver indicators Follow this check without opening live or wet electrical equipment. ⌄
Process
Inspect externally for power, heat or damage.
Fix 3 — Leave wet or damaged fittings isolated Follow this check without opening live or wet electrical equipment. ⌄
Process
Do not repeatedly retry the circuit.
Common causes explained Why outdoor electrical faults develop. ⌄
Garden lights may fail because of a tripped RCD, failed transformer or driver, timer or photocell setting, broken cable, failed lamp group, poor joint or water ingress.
Outdoor circuits face rain, condensation, temperature changes, ground movement and mechanical damage. A fault that disappears in dry weather is still a real insulation or sealing problem.
Advanced diagnostics Technician-level testing for a competent electrician. ⌄
- Test transformer or driver input and output.
- Inspect photocell and timer outputs.
- Carry out insulation-resistance testing on mains sections.
- Check low-voltage continuity and voltage drop.
- Inspect buried joints, glands and fitting seals.
Parts that may need replacing Common components linked to this fault. ⌄
- Transformer
- LED driver
- Photocell
- Timer
- Garden light fitting
- Waterproof junction
- Outdoor cable
When to call an electrician Conditions that should end DIY troubleshooting. ⌄
- There is water inside a socket, fitting, board or junction.
- The RCD or breaker repeatedly operates.
- A shed or garage submain is involved.
- Cable damage, digging or impact is suspected.
- The accessory is cracked, burnt, corroded or pulling away.
- The fault remains with portable equipment disconnected.
Frequently asked questions Common questions about outdoor electrical faults. ⌄
Can I use an outdoor socket after it dries?
Not until the cause of water entry has been repaired and the circuit tested.
Why does the fault happen only in rain?
Moisture lowers insulation resistance and exposes failed seals, joints or cable damage.
Can one outdoor appliance trip the whole house?
Yes. One faulty outdoor item can trip an RCD protecting several indoor circuits.