Stop if there is heat, burning, arcing, exposed parts or damaged supply equipment
Do not remove consumer-unit covers, open electricity meters, disturb sealed cut-outs or touch exposed conductors. Leave affected equipment off and contact a registered electrician, supplier or network operator as appropriate.
MOST LIKELY CAUSES
Start with these
Symptom variations Match the exact pattern before testing. ⌄
- Some sockets and lights work while others do not
- One side of the consumer unit appears off
- Upstairs works but downstairs does not
- Power returns after resetting one RCD
- The same half trips repeatedly
Quick checks Safe checks using front-panel controls and visible information only. ⌄
- Check whether the whole property or only certain rooms are affected.
- Look for a wider local outage.
- Inspect the consumer unit for a tripped breaker, RCBO, RCD or main device.
- Check the electricity meter display and prepayment status where applicable.
- Attempt one controlled reset only if there are no danger signs.
Fix 1 — Identify the dead areas Follow this check without opening live or sealed electrical equipment. ⌄
Process
List which rooms, lights and sockets are affected.
Fix 2 — Check the RCD group Follow this check without opening live or sealed electrical equipment. ⌄
Process
Move the affected RCD fully to OFF, then reset once.
Fix 3 — Unplug appliances on the dead side Follow this check without opening live or sealed electrical equipment. ⌄
Process
Remove portable loads before another controlled reset.
Common causes explained Why the power or supply may fail. ⌄
When roughly half the property loses power, one side of a split-load consumer unit, one RCD group, several RCBOs or a shared supply connection may have failed.
Power loss can originate inside the property, at the meter, or on the electricity network. Identifying which protective device operated and how much of the property is affected is the quickest way to narrow it down.
Advanced diagnostics Technician-level testing for a competent electrician. ⌄
- Map circuits to the affected RCD or RCBO group.
- Test leakage current and insulation resistance.
- Check neutral bars and shared neutrals.
- Inspect busbar and supply links for heat damage.
- Test permanently connected loads individually.
Parts that may need replacing Components commonly linked to this fault. ⌄
- RCD or RCBO after testing
- Neutral-bar connection
- Busbar or supply link
- Faulty appliance
- Damaged circuit cable
When to call an electrician or supply provider Conditions that should end DIY troubleshooting. ⌄
- The fault remains after one controlled reset.
- There is burning, heat, buzzing, crackling or visible damage.
- The main switch, RCD or breaker will not stay on.
- The meter or sealed supply equipment appears damaged.
- Lights become unusually bright or voltage appears unstable.
- Only your property is affected and no internal protective device has operated.
Frequently asked questions Common questions about supply faults. ⌄
Who should I call for a complete power outage?
Check whether neighbours are affected. A wider outage belongs to the electricity network operator; a fault limited to your installation may need an electrician.
Can a faulty appliance cut power to several rooms?
Yes. One appliance can trip an RCD that protects several circuits.
Should I repeatedly reset the main switch or RCD?
No. One controlled reset is enough to establish whether the fault remains.