Stop if there is heat, burning, arcing, exposed parts or water near electrical equipment
Do not remove covers or test exposed conductors. Leave affected circuits isolated and call a registered electrician or qualified appliance engineer where fixed wiring or internal faults are suspected.
MOST LIKELY CAUSES
Start with these
Symptom variations Match the exact behaviour before testing. ⌄
- Fan runs after the light is off
- Fan never stops
- Fan stops only at isolator
- Fan runs more in damp weather
- Fan began running continuously after replacement
Quick checks Safe checks using controls and front-panel devices only. ⌄
- Check the appliance controls, timer, thermostat, lock and display.
- Confirm the local isolator or fused spur is on and undamaged.
- Inspect the consumer unit for a tripped breaker, RCBO or RCD.
- Look for heat, smell, moisture, buzzing or discolouration.
- Attempt one controlled reset only if no danger signs are present.
Fix 1 — Wait for the full overrun period Follow this check without opening live or fixed electrical equipment. ⌄
Process
Allow the manufacturer's maximum timer delay after the trigger is removed.
Fix 2 — Reduce humidity and check settings Follow this check without opening live or fixed electrical equipment. ⌄
Process
Ventilate the room and adjust accessible humidistat controls within the manual's range.
Fix 3 — Check manual boost or override Follow this check without opening live or fixed electrical equipment. ⌄
Process
Return wall controls, pull cords or smart controls to automatic mode.
Common causes explained Why the appliance or circuit may fail. ⌄
A bathroom fan may keep running because of a normal timer overrun, high humidity, a manual override, stuck relay, failed sensor or incorrect permanent-live and switched-live wiring.
Fixed appliances often use dedicated circuits, isolators, fused spurs and local controls. The fault may be in the appliance, control accessory, cable or circuit protection.
Advanced diagnostics Technician-level testing for a competent electrician. ⌄
- Verify permanent live, switched live and neutral wiring.
- Test timer and humidity-sensor operation.
- Check for a stuck relay or control output.
- Inspect incorrect links after fan replacement.
- Confirm isolator switching arrangement.
Parts that may need replacing Common components linked to this fault. ⌄
- Timer module
- Humidity sensor
- Complete extractor fan
- Relay or controller
- Fan isolator
- Cable connection
When to call an electrician or appliance engineer Conditions that should end DIY troubleshooting. ⌄
- The appliance or isolator is hot, burnt, buzzing or crackling.
- The breaker, RCBO, RCD or fused spur operates repeatedly.
- Water may have reached electrical components.
- The appliance is permanently wired or high current.
- The fault remains after basic external checks.
Frequently asked questions Common questions about fixed appliances. ⌄
Can the appliance fail without tripping the breaker?
Yes. Controls, elements, motors and internal connections can fail while protection remains on.
Should I repeatedly reset the circuit?
No. One controlled reset is enough to confirm whether the fault remains.
Can I fit a larger fuse or breaker?
No. Protection must match the cable and appliance design.